FOR THE INSTALLER
This cookers has class “2/1” overheating protection so that it can be installed next to a
cabinet.
If the cooker is installed adjacent to furniture which is higher than the gas hob cooktop,
a gap of at least 50 mm must be left between the side of the cooker and the furniture.
The furniture walls adjacent to the cooker must be made of material resistant to heat.
The veneered syntetical material and the glue used must be resistant to a temperature of
120°C in order to avoid ungluing or deformations.
The cooker may be located in a kitchen, a kitchen/diner or bed-sitting room but not in a
room containing a bath or shower.
Curtains must not be fitted immediatly behind appliance or within 500 mm of the sides.
It is essential that the cooker is positioned as stated below.
The cooker must be installed by a qualified technician and in compliance
with local safety standards.
Fig. 19
Location
50 mm
750 mm
500 mm
air vent