AWR MTD2 XE
43
HFC 410AAWR_MTD2_XE_0011_0091_201109_EN
T
CONFIGURATION "0"
AWR_MTD2_XE_0000.1
26/01/2011
REV_01
MT
6
7
8
ZONE "1"
9
T
T
F
N.C.
1
5
D
T
2
3
4
ACS
T
T
1
4
2
3
5
6
T
F
MT
7
8
9
MEDIUM TEMPERATURE REVERSE-CYCLE UNIT, MODEL AWR MTD2 XE
HEAT PUMP OUTLET
HEAT PUMP RETURN
DOMESTIC HOT WATER
DOMESTIC COLD WATER
ELECTRICAL CONNECTIONS
INDICATES CLIMAVENETA ACCESSORIES
RUBBER VIBRATION DAMPER KIT FOR FLOOR-STANDING
INSTALLATION
OUTSIDE AIR TEMPERATURE PROBE
(SUPPLIED AS STANDARD WITH THE HEAT PUMP)
REMOVABLE METAL MESH FILTER (1"1/4, 1"1/2 OR 2")
1”1/4 THREE-WAY SELECTOR VALVE FOR DHW PRODUCTION
DHW STORAGE TANK, MODEL HWC 300 OR HWC 500
ELECTRIC HEATER KIT, 1-2-3 kW
STORAGE TANK FOR HEATED AND CHILLED WATER,
MODEL BT35, BT100 OR BT200 (*)
HOT WATER RECIRCULATION
9 ROOM UNIT (SUPPLIED AS STANDARD WITH THE HEAT PUMP)
CLIMAVENETA APPLIANCES
KEY TO THE SYMBOLS
PRESSURE GAUGE
THERMOMETER
FLOW SWITCH
VIBRATION DAMPER JOINT
SHUT-OFF VALVE
“Y” FILTER
SAFETY VALVE WITH
PIPED DISCHARGE
CHECK VALVE
THERMOSTATIC MIXER
VENT VALVE
MEMBRANE EXPANSION
VESSEL
DRAIN VALVE
CALIBRATING VALVE
N.B.: Typical water circuit diagram.
OUTSIDE INSIDE
LOW-LOSS
HEADER
SELF-CLEANING
FILTER
FROM WATER
MAINS
AUTOMATIC FILL
ASSEMBLY