DeLonghi AWR-MTD2-XE Service Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
AWR_MTD2_XE_0011_0091_201109_EN HFC 410A
17
AWR MTD2 XE
HWC DOMESTIC HOT WATER CYLINDER
The HWC storage cylinders are made especially for domestic
hot water production in combination with heat pumps, thanks to
the inside coil with large heat exchange area.
The heat pump is connected to the inside coil that heats the
domestic hot water contained in the storage tank.
Legionella prevention cycles are managed by an electric heater
that can be installed in the fitting provided on the flange.
The Legionella prevention cycles are managed by the NadiSys-
tem controller on the heat pump.
Technical specifications
The cylinders are made from
S275JR steel plate in accordance
with DIN 4753 and undergo strict
water pressure tests (9 bars,
allowing an operating pressure of
6 bars). Lined on the inside with
double layer of enamel in accor-
dance with DIN 4753.
Protection against corrosion guar-
anteed by the magnesium anode,
provided with the accessories
supplied as standard with the
storage cylinder. The cylinders
are protected on the outside by
50 mm rigid CFC-free PUR lining
with white skai casing.
The combinations proposed exclude the 0061 and 0091 heat pumps, which
require the TPS series storage tanks.
Models available Volume
HWC300 300 litres
HWC500 500 litres
Storage cylinder and heat pump combinations
Storage
cylinder
Coil water
content
Coil sur-
face area
Combined heat pumps
(l) (m
2
) 11 25 31 41 51 61 91
HWC 300 22,3 3,5 x x x N.A N.A
HWC 500 38,5 5,9 x x x x x N.A N.A
System
N.C.
AUTOMATIC
FILL ASSEMBLY
LOW-LOSS
HEADER
FROM WATER
MAINS
SELF-CLEANING
FILTER
The diagram shown is purely indicative.
Water circuit diagram
Use Dimensions 300 500
A
Height
with insulation - mm 1570 1800
B without insulation - mm - -
C
Diameter
with insulation - mm 650 750
D without insulation - mm 550 650
E Cold water
height - mm 140 155
fitting - R” 1 ¼” 1 ¼”
F
Hot water
height - mm 1570 1800
fitting - R” 1 ¼” 1 ¼”
G Recirculation
height - mm 1200 1400
fitting - R” ½” ½”
H
Flange with 2" bushing
for electric heater
height - mm 295 310
Ø - mm 180/120 180/120
fitting - R” 2” 2”
J
Heat pump
outlet
height - mm 920 1185
fitting - R” 1 ¼” 1 ¼”
K
Heat pump
return
height - mm 240 255
fitting - R” 1 ¼” 1 ¼”
N Thermometer
height - mm 1350 1550
fitting - R” ½” ½”
O
Probe socket
height - mm 1570 1800
fitting - R” ½” ½”
P Probe socket
height - mm - 600
fitting - R” - ½”
Q Magnesium anode
height - mm 1570 1800
fitting - R” 1 ¼” 1 ¼”
R Magnesium anode
height - mm - 1400
fitting - R” - 1 ¼”
Weight with insulation
kg 145 220
Water content heat exchange
l 22,3 38,5
Surface area heat exchanger
m
2
3,5 5,9
F
F
Dimensions - Model HWC300
Dimensions - Model HWC500