DeLonghi 28K Owner's Manual

Browse online or download Owner's Manual for Split-system air conditioners DeLonghi 28K. DeLonghi 28K Owner`s manual [en] User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Split Air Conditioner

Split Air ConditionerThank you for choosing DE'LONGHI air conditioner. For correct opertion,please read this owner’s manual carefully before oper

Page 2 - CONTENTS

start to blink and enter into clock adjustment status.Introduction for special function 1. After powered on, press ON/OFF button, the unit will start

Page 3 - Earth: The ground

4.2.3.★●●●●●Slightly to press the place with , along the arrowhead direction to push the back cover of wireless remote control. (As show in fig

Page 4 - Notices for operation

If the wireless remote control is lost or broken, please use the manual switchAuto mode, but the temperature and fanbutton. At this time, the unit wil

Page 5 - Notices for use

11●● ● ●Emergency Operation (only on some models)Emergency OperationWhen the wireless remote control is lost or damaged, please use the manual switch,

Page 6 - Indoor unit

℃●●●●●℃② Clean the air filter③①(a)(b)Clean and care CautionTurn power off and pull out the power plug before cleaning air conditioner, or it may cause

Page 7 - 遥控器各按键的名称及作用

① Be sure that nothing obstructs the air outlet and intake vents.② ③ Check that whether the batteries of air conditioner are changed or not.④ Ch

Page 8 - - button

Once the air conditioner is stopped, it willnot operate in approximately 3minutes toprotect itself.●●●●●●TroubleshootingCAUTIONDon't attempt to r

Page 9 - TIMER OFF BUTTON

●●●●●●●●●●●●●●●●●●●●●●TroubleshootingPhenomenonTroubleshootingThe unit can not run.Has the power been shut down?Is power plug loosed?Is the circuit pr

Page 10 - About AUTO function

●●●●TroubleshootingPhenomenonTroubleshootingIndoor unit cannot deliver air.Moisture on air outlet vent.If unit is running under the high humidity fora

Page 11 - Sketch map for

1.2.Select a position where the condensing water can be easily drained out, and the placeis easily connected for outdoor unit.4.Can select the place w

Page 12 - Emergency operation

CONTENTSThis symbol stands for the itemsshould be forbidden.This symbol stands for the items should be followed ...1

Page 13 - Emergency Operation

Note:Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected, there should be reliab

Page 14 - Clean and care

Space to the wallAboveAboveInstallation dimension diagramInstallation dimension diagramSpace to the ceilingSpace to the wallSpace to the wallAir outle

Page 15 - Check before use

20Install indoor unit 1 5 0mm φ 6 5mm φ6 5mm 1 5 0mm Ø 65 5 Install the rear panel 1.Always mount the rear panel horizontally. Due to the water tray

Page 16 - Troubleshooting

21●●● After tighten the screw, slight pull the wire and confirm whether is it firm or not.● ● The cover plate must be fixed, and tighten the connectio

Page 17

ØAir purging and leakage testCondensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in th

Page 18

1.(1)Do not switch on power before installation isfinished completely.(2)Electric wiring must be connected correctly and securely.(3)Cut-off valves of

Page 19

Fig. aInstallation Instructions1. Forcibly pull the panel for a specific anglefrom the two ends of the front panel accordingto the arrow direction. Th

Page 20

9K 12K 18K 24K 28KGeneral dataElectricity supply230~50 (*)V~HzRefrigerant gasR410 A (**)Fuse 10 10 16 20 20 AMinimum cable section 1,0 1,0 2,5 2,5 mm1

Page 21 - Space to the ceiling

Operating limitsInternal part bulb External part bulbCooling (Max ;Min) 32 ;21 43 ; 21CHeating (Max ; Min) 27 ; 20 24 ; -5MODELSIinch10 10 10

Page 23 - Finally wrap it

★★★Operation and maintenance-notices for operation1★ ★ Be sure to pull out the power★★★★Earth: The groundbe connected! If not, please ask the q

Page 26 - Service Life

5717310161/06.10/0166129905672

Page 27 - TECHNICAL DATA

2★★★★★★★★Notices for operationIf the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified per

Page 28 - TECHNICAL DATA - INVERTER

.Anti-cool wind function:In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain t

Page 29

Names and functions of each part⑸⑻⑶⑴⑵⑹⑸⑵⑻⑷⑺⑶⑴Indoor unitAir inAir outOutdoor unitWirelessremote controlRemote controlFront panelFilterGuide louverWall

Page 30

遥控器各按键的名称及作用5Names and functions of wireless remote control● Press this button, the unit will be turned on, press it once more, the unit will ON/OFF b

Page 31

● Press this button, can select:setting temperature ( ), indoor ambient tempe-TEMP buttonrature( ),outdoor ambient temperature( ).These tem

Page 32 - 66129905672

Timer On setting: "ON" flashes andwill conceal,numeral segment become timer-on setting status.Pressingor could adjust the numeral segm

Comments to this Manuals

No comments