Warranty/technical specifications
WARRANTY AND TECHNICAL SERVICE
The conditions of the warranty and technical
service are provided on the certificate sup-
plied with your appliance.
LIMIT CONDITIONS
Temperature in the room 21 ÷ 32°C
Outside temperature 21 ÷ 43°C
TECHNICAL SPECIFICATIONS
Power supply voltage see rating plate
Max. power input during
air conditioning
Max. power input during
dehumidifying “
Cooling capacity*
Number of fan speeds 3
Max. air flow-rate 250-350 m
3
/h
Dimensions of indoor unit:
width 450 mm
height 475 mm
depth 255 mm
•weight 10 kg
Dimensions of outdoor unit
width 570 mm
height 542 mm
depth 280 mm
•weight 30 kg
* Standard conditions:
Inside temperature 27°C
47% relative humidity
Outside temperature 35°C
41% relative humidity
R407c is a refrigerant that complies with the EU rules on the environment, therefore it is recom-
mended to not perforate the unit’s refrigerant circuit.
At the end of its working life, take the appliance to a special collection centre.
ELECTRICAL CONNECTION (U.K. ONLY)
A) If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket,
the plug should be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very
carefully dispose of the cut off plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in
the house as this could cause a shock hazard. With alternative plugs not incorporating a fuse, the circuit
must be protected by a 15 Amp fuse. If the plug is a moulded-on type, the fuse cover must be re-fitted
when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. In the event of losing the fuse
cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nearest elec-
trical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.
B) If your appliance is not fitted with a plug, please follow the instructins provided below:
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accor-
dance with the following code:
Green and yellowEarth
Blue Neutral
Brown Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
The green and yellow wire must be connected to
the terminal in the plug marked with the letter E or
the earth symbol or coloured green or green
and yellow.
The blue wire must be connected to the terminal
marked with the letter N or coloured black.
The brown wire must be connected to the terminal
marked with the letter L or coloured red.