DeLonghi PAC A120E Specifications Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
17
Technical specification
LIMIT CONDITIONS
Room temperature for
air conditioning 64 ÷ 95°F (18° ÷ 35°C)
TECHNICAL SPECIFICATION
Power supply voltage see rating plate
Max. absorbed power
during air conditioning
Refrigerant
Cooling capacity
Dimensions of appliance:
width 18 in - 463 mm
height 30 in - 775 mm
depth 15 in - 382 mm
weight 70 lb - 32 kg
SAFETY PLUG
The appliance is fitted with a safety plug to protect the power cable.
If power is cut off, unplug from the mains and make sure the power cable is undamaged.
If the cable is damaged, call the service center immediately.
If power cuts off frequently and the power cable is undamaged, contact a qualified elec-
trician.
OPERATION OF THE SAFETY PLUG
If the safety device incorporated in the plug trips and cuts off the power supply, check
that the power cable and plug are not damaged.
If the power cable is undamaged, to restore operation press the "RESET" button.
To verify correct operation of the plug, press the "TEST" button periodically and make sure
the appliance disconnects. If this is not the case, contact the service center.
To restore operation, press the "RESET" button.
NEVER TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE.
IF THIS OCCURS, WAIT AT LEAST 4 HOURS BEFORE TURNING THE APPLI-
ANCE ON
Transport, filling, cleaning, recovery and dis-
posal of refrigerant should be performed by
a technical service centre appointed by the
manufacturer only.
The appliance should be disposed of by a
specialist centre appointed by the manu-
facturer only.
This appliance is equipped with a 3 prong grounding plug. The plug must be connected into
an outlet that is properly installed and grounded in the accordance with all local codes
and ordinances. Do not modify the plug provided with the appliance. If it will not fit the
outlet, have a proper outlet installed by a qualified electrician.
If the household electrical supply does not meet the above specifications, or if you are not
sure your home has an effective ground, have a qualified electrician or your local electrical
utility company check it and correct any problems.
Page view 16
1 2 ... 12 13 14 15 16 17 18

Comments to this Manuals

No comments